Mostrar el registro sencillo del ítem

dc.contributor.authorBusto, L.*
dc.contributor.authorVeiga Garcia, Cesar*
dc.contributor.authorGonzález-Nóvoa, J.A.*
dc.contributor.authorCampanioni, S.*
dc.contributor.authorJuan Salvadores, Pablo*
dc.contributor.authorJiménez Díaz, Victor Alfonso*
dc.contributor.authorBaz Alonso, José Antonio *
dc.contributor.authorAlba-Castro, J.L.*
dc.contributor.authorKütting, M.*
dc.contributor.authorIñiguez Romo, Andres *
dc.date.accessioned2025-09-08T11:51:54Z
dc.date.available2025-09-08T11:51:54Z
dc.date.issued2023
dc.identifier.citationBusto L, Veiga C, González-Nóvoa JA, Campanioni S, Juan-Salvadores P, Jiménez Díaz VA, et al. Automatic Assessment of Transcatheter Aortic Valve Implantation Results on Four-Dimensional Computed Tomography Images Using Artificial Intelligence. Bioengineering. 2023;10(10).
dc.identifier.issn2306-5354
dc.identifier.otherhttps://portalcientifico.sergas.gal//documentos/6550d9f992517a5a7db94d63
dc.identifier.urihttp://hdl.handle.net/20.500.11940/21219
dc.description.abstractTranscatheter aortic valve implantation (TAVI) is a procedure to treat severe aortic stenosis. There are several clinical concerns related to potential complications after the procedure, which demand the analysis of computerized tomography (CT) scans after TAVI to assess the implant's result. This work introduces a novel, fully automatic method for the analysis of post-TAVI 4D-CT scans to characterize the prosthesis and its relationship with the patient's anatomy. The method enables measurement extraction, including prosthesis volume, center of mass, cross-sectional area (CSA) along the prosthesis axis, and CSA difference between the aortic root and prosthesis, all the variables studied throughout the cardiac cycle. The method has been implemented and evaluated with a cohort of 13 patients with five different prosthesis models, successfully extracting all the measurements from each patient in an automatic way. For Allegra patients, the mean of the obtained inner volume values ranged from 10,798.20 mm3 to 18,172.35 mm3, and CSA in the maximum diameter plane varied from 396.35 mm2 to 485.34 mm2. The implantation of this new method could provide information of the important clinical value that would contribute to the improvement of TAVI, significantly reducing the time and effort invested by clinicians in the image interpretation process.
dc.description.sponsorshipThis research was partially supported by Axencia Galega de Innovacion and New Valve Technology. The authors would like to thank the Cardiovascular Research Unit in Alvaro Cunqueiro Hospital for their support in the identification of patient studies.
dc.languageeng
dc.rightsAttribution 4.0 International (CC BY 4.0)*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.titleAutomatic Assessment of Transcatheter Aortic Valve Implantation Results on Four-Dimensional Computed Tomography Images Using Artificial Intelligence
dc.typeArtigo
dc.authorsophosBusto, L.; Veiga, C.; González-Nóvoa, J.A.; Campanioni, S.; Juan-Salvadores, P.; Jiménez Díaz, V.A.; Baz, J.A.; Alba-Castro, J.L.; Kütting, M.; Íñiguez, A.
dc.identifier.doi10.3390/bioengineering10101206
dc.identifier.sophos6550d9f992517a5a7db94d63
dc.issue.number10
dc.journal.titleBioengineering*
dc.organizationInstituto de Investigación Sanitaria Galicia Sur (IISGS)
dc.organizationInstituto de Investigación Sanitaria Galicia Sur (IISGS)
dc.organizationServizo Galego de Saúde::Áreas Sanitarias (A.S.) - Complexo Hospitalario Universitario de Vigo::Cardioloxía
dc.organizationServizo Galego de Saúde::Áreas Sanitarias (A.S.) - Complexo Hospitalario Universitario de Vigo::Cardioloxía
dc.organizationServizo Galego de Saúde::Áreas Sanitarias (A.S.) - Complexo Hospitalario Universitario de Vigo::Cardioloxía
dc.relation.projectIDAxencia Galega de Innovacion and New Valve Technology
dc.relation.publisherversionhttps://doi.org/10.3390/bioengineering10101206
dc.rights.accessRightsopenAccess*
dc.subject.keywordIISGS
dc.subject.keywordIISGS
dc.subject.keywordAS Vigo
dc.subject.keywordCHUVI
dc.subject.keywordAS Vigo
dc.subject.keywordCHUVI
dc.subject.keywordAS Vigo
dc.subject.keywordCHUVI
dc.typefidesArtículo Científico (incluye Original, Original breve, Revisión Sistemática y Meta-análisis)
dc.typesophosArtículo Original
dc.volume.number10


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution 4.0 International (CC BY 4.0)
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution 4.0 International (CC BY 4.0)