Mostrar el registro sencillo del ítem

dc.contributor.authorSoler-Alcaraz, S.*
dc.contributor.authorGuerrero-Sánchez, Y.*
dc.contributor.authorPérez Sayáns, Mario*
dc.contributor.authorBernabeu-Mira, J.C.*
dc.contributor.authorPeñarrocha-Oltra, D.*
dc.contributor.authorCamacho-Alonso, F.*
dc.date.accessioned2025-09-09T11:19:25Z
dc.date.available2025-09-09T11:19:25Z
dc.date.issued2023
dc.identifier.citationSoler-Alcaraz S, Guerrero-Sánchez Y, Pérez-Sayáns M, Bernabeu-Mira JC, Peñarrocha-Oltra D, Camacho-Alonso F. Evaluation of Change in Radiographic Fractal Dimension around Dental Implants Placed with Low-Speed Drilling and Standard Drilling Protocols. Journal of Clinical Medicine. 2023;12(6).
dc.identifier.issn2077-0383
dc.identifier.otherhttps://portalcientifico.sergas.gal//documentos/6444ede148c3090deaa261e5
dc.identifier.urihttp://hdl.handle.net/20.500.11940/21454
dc.description.abstractOsseointegration is a process that depends on a multitude of factors, including the type of drilling, whether biological or conventional. Objective: Establish box-counting dimension values for radiological images in patients with implants placed with both drilling methods. Material and method: The sample included 129 implants corresponding to 50 patients. A double-blind study of data collection was carried out with the subsequent analysis of the fractal dimension as a comparative value of the state of the trabecular architecture. Results: We found no significant differences (p ? 0.05) between the two study groups comparing both drilling techniques. The values for the conventional drilling technique are 0.24 ± 0.07 and for biological drilling: 0.19 ± 0.11 with a p-value of 0.767. Conclusions: The drilling technique does not influence the success of the procedure and the osseointegration process.
dc.description.sponsorshipThis paper has been supported by Master en Cirugia e Implantologia Bucal, Hospital Morales Meseguer, Department of Oral Surgery, University of Murcia, Spain.
dc.languageeng
dc.rightsAttribution 4.0 International (CC BY 4.0)*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.titleEvaluation of Change in Radiographic Fractal Dimension around Dental Implants Placed with Low-Speed Drilling and Standard Drilling Protocols
dc.typeArtigo
dc.authorsophosSoler-Alcaraz, S.; Guerrero-Sánchez, Y.; Pérez-Sayáns, M.; Bernabeu-Mira, J.C.; Peñarrocha-Oltra, D.; Camacho-Alonso, F.
dc.identifier.doi10.3390/jcm12062244
dc.identifier.sophos6444ede148c3090deaa261e5
dc.issue.number6
dc.journal.titleJournal of Clinical Medicine*
dc.organizationServizo Galego de Saúde::Áreas Sanitarias (A.S.) - Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS)
dc.relation.projectIDMaster en Cirugia e Implantologia Bucal, Hospital Morales Meseguer, Department of Oral Surgery, University of Murcia, Spain
dc.relation.publisherversionhttps://doi.org/10.3390/jcm12062244
dc.rights.accessRightsopenAccess*
dc.subject.keywordAS Santiago
dc.subject.keywordIDIS
dc.typefidesArtículo Científico (incluye Original, Original breve, Revisión Sistemática y Meta-análisis)
dc.typesophosArtículo Original
dc.volume.number12


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution 4.0 International (CC BY 4.0)
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution 4.0 International (CC BY 4.0)